High-pressure CR Diesel pump: power and efficiency for diesel engines

The high-pressure pump in a common-rail system is capable of generating enormously high pressures. The seals are continuously put to the test. Due to the large quantity of fuel pumped, wear and tear will eventually be inevitable. The pumped fuel is not only used for injection through the injector but is also used to cool the high-pressure pump itself. It is therefore easy to imagine that, after a long time, the operation is no longer optimal and replacement is required. A replacement pump is then a good option. Of these, the quality can match new with a more attractive price. Diesel Büchli has the largest stock of spare parts of all original brands. So you can quickly get on with your work.

Possible causes failure of high-pressure CR pumps;

  • External contamination
  • Normal wear and aging
  • Lubricating properties of the fuel failing
  • Electrical coil defective
  • Electrical control disturbed

Total 612 products in group high-pressure cr diesel pumps

BANKED-PISTON-PUMP 0445020068
Robert Bosch
High-pressure pump 0445020091
Robert Bosch
High-pressure pump 0445020126
Robert Bosch
High-pressure pump 0445020135
Robert Bosch
High-pressure pump 0445020158
Robert Bosch
High-pressure pump 0445020165
Robert Bosch
High-pressure pump 0445020191
Robert Bosch
High-pressure pump 0445020195
Robert Bosch
High-pressure pump
High-pressure pump 0445020200
Robert Bosch
High-pressure pump 0445020213
Robert Bosch
High-pressure pump 0445020216
Robert Bosch
High-pressure pump 0445020234
Robert Bosch
BANKED-PISTON-PUMP 0445020235
Robert Bosch
High-pressure pump 0445020237
Robert Bosch
High-pressure pump 0445020240
Robert Bosch
High-pressure pump 0445020249
Robert Bosch
High-pressure pump 0445020260
Robert Bosch
High-pressure pump 0445020266
Robert Bosch
High-pressure pump 0445020271
Robert Bosch
High-pressure pump 0445020293
Robert Bosch
High-pressure pump 0445020303
Robert Bosch

What is the difference between repair and overhaul?

To repair is to replace or fix what caused the defect. In other words; removing the reason why something no longer works.

Overhaul goes much further, replacing not only the defective parts but also those that could prevent trouble-free operation in the long run, as well as any modifications. The reliability of a reconditioned unit can match new. All this at lower costs and environmentally responsible by reusing parts.

To ensure proper operation, it is very important to follow the manufacturer’s installation instructions carefully. Working cleanly is an absolute necessity. It goes without saying that any cause of pump failure must be eliminated prior to installation.